MedFabric: Gold Evidence Hides the Difficulty of Word-Level Medical Fabrication Detection
Authors: Tung Sum Thomas Kwok, Qian Qian, Xiaofeng Lin, Dongxu Zhang, Jun Han, Zhichao Yang, Davin Hill, Tamer Soliman, Sanjit Singh Batra, Robert Tillman, Guang Cheng
Abstract
Large language models fabricate in medicine, producing fluent statements that are factually wrong, so reliable fabrication detection is a prerequisite for clinical deployment. Reported progress on this task is inflated by two evaluation artifacts: an authorship-style shortcut, where human-written ground truths are paired with LLM-written hallucinations so detectors key on writing style rather than facts, and the provision of gold evidence at test time. A benchmark that tests factual reasoning must therefore remove the style shortcut, ground every fabrication in a real retrievable passage, and score detectors across the range of evidence quality faced in deployment. We build MedFabric to these requirements, a benchmark of 646 word-level medical fabrications, each paired with a ground truth that shares its LLM authorship and near-identical surface form (median ROUGE-L 0.95). On MedFabric the task is unsolved: expert clinicians reach only 53.3% macro F1 and no detector family clears about 60% without gold evidence. Our central finding is that detection is governed by evidence correctness rather than fabrication subtlety, since a strong LLM scores 91% with the gold passage but falls to 35%, below its own no-evidence baseline, under a wrong one, a pattern that holds on two benchmarks at two model scales. The failure is actionable: a retrieval-confidence gate that abstains on low-confidence evidence raises macro F1 from 61% to 74%, and we release MedFabric, all code, and every baseline.